TTIPE Series 10-120KVA

FEATURES

  • High frequency online double-conversion with DSP control
  • Modular design, high reliability, easily maintenance
  • Double input distribution, higher reliability of system
  • Input power factor correction (PFC)
  • Wide input voltage range, 50Hz/60Hz frequency self-adaptable
  • Support two modes of frequency conversion: 50Hz input/60Hz output and 60Hz input/50Hz output
  • Input power factor>0.99, input THDi=s3%, output THDV=s3%
  • Output power factor 0.9
  • High efficiency: load>10%, efficiency=90%; load>50%,efficiency&93%.
  • Digitized charger: flexible charger parameter and battery configuration setting, monitoring battery disconnected on line
  • Snare Dattery packin paralier operation or separate Dattery раck for different UPS
  • Support battery cold start and mains supply self-starting
  • 5.7 inches LCD touch screen, friendly human & machine interface
  • Perfect protective function in hard and software, robust self diagnose, abundant event log for future check
  • Perfect password control technology, including: the first power-on password control, user password control and Maintenance password control.
  • Reminders of battery and DC BUS capacitors out of warranty
  • Standard emergency power off (EPO)
  • Standard RS232/USB/RS485/Dry contact communication port
  • Optional SNMP communication port
  • Optional N+1 redundancy parallel up to 6 units
  • Optional built-in isolation transformer
  • Optional battery temperature compensation
Enquiry Now
Category:

TECHNICAL SPECIFICATIONS

MODEL TTIPE12010 TTIPE12020 TTIPE12030 TTIPE12040 TTIPE12060 TTIPE12080 TTIPE12100 TTIPE12120
Capacity 10KVA 9KW 20KVA 18KW 30KVA 27KW 40KVA 36KW 60KVA 54KW 80KVA 72KW 100KVA 90KW 120KVA 108KW
INPUT

Rated Voltage

380V/400V/415VAC
  304V-520VAC (Load100%)

Rated Frequency

50/60HZ Auto Sensing

Frequency Range

40-70HZ

Total Harmonic
Distortion(THDI)
<3%
OUTPUT

Voltage

380V/400V/415VAC

Voltage Regulation

±1%

Frequencу

Synchronized with utility on AC mode;
 

(Frequency converter mode:50Hz input and 60Hz output or 60Hz input and 50Hz output)

  50/60Hz on battery mode
Waveform >Pure Sine Wave

Crest Factor

3:01

Total Harmonic
Distortion(THDV)

≤1%(Linear load); ≤3%(Non-linear load)
Transfer Time Between AC mode and battery mode :0ms
  Between AC model and bypass mode:0ms
Inverter Overload
Capability
101%-125%:Transfer to bypass after 10mins;
  125%-150%:Transfer to bypass after 1 mins;
  >150%: Transfer to bypass after 0.5s
Bypass Overload
Capability
<150%: Long time running
  >150%: Shut down after 10s
BATTERY

DC Voltage

+ 192V(Option: ± 204V/± 216V/± 228V/± 240V)
Inbuilt Battery of
Standard Model
32*12V/7Ah 64*12V/7Ah NO  
SYSTEM

Efficiency

≥93%,ECO model 98.5%

Display Panel

5.7 Inches LCD touch screen

Alarm

Battery mode, Battery voltage low, Fans fault etc
Maximum Parallel
numbers
6

EMI

EN62040-2
EMS IEC61000-4-2(ESD)
  IEC61000-4-3(RS)
  IEC61000-4-4(EFT)
  IEC61000-4-5(Surge)
ENVIRONMENT
Humidity 0-95% RH @ 0~40-C(non-condensing)

Noise Level

≤60dB( at 1 Meter)
MANAGEMENT
Communication RS232.RS485, USB,Dry contact
  RS232.RS485, USB,Dry contact

Optional SNMP

Power management from SNMP manager and web browser
PHYSICAL

Dimension(mm)
W*D*H/td>

600x800x1360 600x800x1680
Packing
Dimension(mm)
W*D*H
720x920x1500 720x920x1820

Net/Gross Weight(kg)
Without Inbuilt battery

180/200 185/205 190/210 225/245 230/250 336/376 374/414
  • All specifications are subject to change without prior notice.
  • Custom-made specifications are acceptable.

Description

Application:
Computer/critical servers/data center/hub & other network device/LAN/WAN.