| INPUT |
| Rated AC Voltage |
380/400/415V(L-L) |
| Type of Input Power |
50/50Hz(+5Hz) |
| Power factor |
>0.82( >0.92, with fiter) |
>0.85(>0.94,with fiter) |
| Harmonic distortion (THDI) |
<20%(<8%,,with fiter) |
| Voltage Range |
285~500Vac |
| Frequency range |
45~66Hz |
| Power Stepping Time |
5-300 seconds,(settable) |
| BYPASS |
| Rated voltage |
380/400/415V(L-L) |
| Voltage Range |
+20%,-40%, (settable) |
| Type of Input Power |
3 Phase+Neutral+РE |
| Frequency range |
50/60Hz±10%(settable) |
| Transient Overload |
15In, 10ms; 5In, 5s |
| DC Bus Battery |
| Battery voltage |
384Vdc(default 32, 30-34, settable) |
| Ripple voltage Superimposed |
|
| Charge current Max. |
9.1A |
18.2A |
27.3A |
36.4A |
54.6A |
72.8A |
91A |
109A |
|
| Output |
|
| Nominal power |
10kVA |
20KVA |
30KVA |
40KVA |
60KVA |
80KVA |
100KVA |
120KVA |
|
| Active power |
8kW |
16kW |
24kW |
32kW |
48kW |
64kW |
80kW |
96kW |
|
| Rated Voltage |
380/400/415V(L-L) |
| Frequency range |
Sync.,the same as the bypass input, 50/60±3Hz(settable) |
|
Free running, 50/60(1±0.05%)Hz |
| Type of Input Power |
3 Phase+Neutral+PРE |
| Votage regulation |
±0.5% |
| Harmonic distortion (with linear load) |
THD<1.5%(phase voltage) |
THD<1.5% (phase voltage) |
| Harmonic distortion (with non linear load) |
THD<12%(phase voltage) |
THD<8%(phase voltage) |
| Frequency stability on battery |
±0.05%Hz |
| Inverter Overload |
100%~105%, long; 105%~110%, 60min; 110%~125% 10min; 125%~150% 1min |
| Bypass<->inverter transfer time |
Oms,with sync.,<15ms without sync. |
| Normal<->Battery mode transfer time |
Oms |
| Crest factor |
3:01 |
| Efficiency |
91.00% |
| Other |
| Parallel |
up to 6 units, redundant (optional) |
| Ioop current |
4%(1+1) |
|
5%(1+N) |
| Noise level at 1 m |
≤65DB |
| Noise level at 1 m |
≤65DB |
| Display |
4 line, LCD+LED/touch screen(optional) |
| Communications |
RS232+RS485, 8 dry contact signals, SNMP card(optional) |
| Protection |
input under/over voltage, over temperature, over current, over load, DC bus over voltage |
| Cold start |
standard |
| Battery temperature compensation |
optional |
| Moving the UPS |
wheel |
forklift |
| Operating temperature |
0~40°C |
| Storage/Transport Temperature |
-25~75°C |
| Altitude |
≥ 1000m a.s.l. de-rate power by 1% per 100m between 1000 and 2000 m |
| IP rating |
IP20/IP21 |
| Standards |
Safety: IEC60950-1, IEC62040-1-1, UL1778, EMC: IEC62040-2 CLASS C2, EN50091-2 CLASS A, |
| H (mm) |
1100 |
1400 |
1600 |
|
| W (mm) |
430 |
720 |
880 |
|
| D (mm) |
830 |
690 |
760 |
|